Electric shock occurs when current passes through the body.
('text', 'Electric shock occurs when current passes through the body.')
Severity depends on voltage, frequency, duration of contact, body resistance (wet skin lowers it) and the path the current takes through the body.
('text', 'Severity depends on voltage, frequency, duration of contact, body resistance (wet skin lowers it) and the path the current takes through the body.')
Incidents and electrical fires are likely when: equipment is unsuitable; inadequately maintained; defective or damaged; used in wet environments; or overheated (for example when charging portable equipment).
('text', 'Incidents and electrical fires are likely when: equipment is unsuitable; inadequately maintained; defective or damaged; used in wet environments; or overheated (for example when charging portable equipment).')
Secondary effects include falls from height after a shock.
('text', 'Secondary effects include falls from height after a shock.')
Tip: A small current through the heart can kill, so the path matters as much as the voltage.
11.2 Control measures
Protect conductors with insulation and enclosure; use equipment that is strong enough and suited to the job and place; and use competent people.
('text', 'Protect conductors with insulation and enclosure; use equipment that is strong enough and suited to the job and place; and use competent people.')
Protective systems and their advantages and limits:
Fuses and circuit breakers (protect against overload and short circuit, not against shock)
Earthing (gives a safe path for fault current)
Isolation of the supply (the safest way to work on equipment)
Double insulation (no earth needed, but damage to the casing can expose live parts)
Residual current devices (cut the supply quickly in a fault, but they need testing and do not prevent all shocks)
Reduced and low voltage systems (they limit the voltage, and so the harm that a fault can cause)
Safe systems of work: no live working unless there is no alternative; isolate and lock off; locate buried services before digging; and protect against overhead lines.
('text', 'Safe systems of work: no live working unless there is no alternative; isolate and lock off; locate buried services before digging; and protect against overhead lines.')
Inspection and maintenance:
User checks before use
Formal inspection and tests of installations and equipment
Frequency based on the risk
Records kept
Portable appliance testing (PAT), which has advantages (finds faults) and limitations (only shows the condition at the time and does not find all faults)
Tip: No single device is enough, so layer your protection.