10.3 Fire Alarms and Fire-Fighting

Common fire detection and alarm systems

Fire detection systems are designed to discover fires early in their development, while there is still time for occupants to evacuate safely. Early detection also plays a significant part in protecting the safety of emergency response personnel. Property loss can be reduced and operating downtime minimised, because control efforts start while the fire is still small.

Detectors respond differently to fires, so where possible the detector should suit the risk:

SmokePhotoelectric:smoulderingIonisation: fast burningHeatRate of rise or fixedtemperatureSlower to respondFlameUV or infra-redBoilers and furnaces
Figure 10.10 Fire detectors

Smoke detectors are very common. They:

Heat detectors suit certain applications. They:

Flame detectors are generally used in industrial settings, for example on boilers and furnaces. They:

Select a suitable warning system through the fire risk assessment and applicable requirements. Many workplaces need an electrically operated system with appropriately positioned call points; some small simple premises may use another adequate arrangement. Competent design must address the actual occupants and layout. It should have enough sounders for the warning to be heard clearly throughout the workplace. The sound should be distinct from other sounds in the workplace and, where background noise is high or an employee has a hearing impairment, it may be necessary to add a visual alarm such as a distinctive flashing or rotating light.

In more complex buildings, such as retail premises where evacuation is staged or phased, or where people are unfamiliar with the fire warning arrangements, consider installing a voice evacuation system. This could form part of a public address system and give both fire warning signals and verbal instructions in the event of fire.

Where a public address system is used together with a fire warning system, both should override any other function of the equipment, such as playing music. The public address element should give clear verbal instructions and should override the fire warning signal, which should be distinct from other signals in general use.

If an automatic fire detection system and a manually operated electrical alarm system are installed in the same workplace, they should normally be combined into a single integrated system. Voice evacuation systems should be integrated in the same way to prevent confusion.