11.2 Control Measures
Pages in this chapter (8 of 9)

Emergency procedures following an electrical incident

Train all workers to take these steps if someone receives an electric shock.

1Power offSafe isolation;no improvisedrescue2Do not touchStay clear ofthe casualty3Call for helpEmergencyservices4First aidRecoveryposition or CPR5Follow upMedical check
Figure 11.9 Responding to an electric shock
  1. Prevent another casualty. Raise the alarm and arrange safe isolation. Switch off only if it is safe to do so; do not approach high-voltage equipment or fallen lines. Keep clear until the supply owner or authorised competent person confirms safety. Do not improvise a rescue using wood, plastic or another item assumed to be insulating.
  2. Do not touch the person who received the shock. If someone is in direct contact with electricity, do not touch them under any circumstances. Stay calm and keep away.
  3. Call the emergency services. Call for help in the case of an electrical hazard. This will include staff trained in emergency first aid.
  4. Give first aid.
    • Once the electrical danger is controlled, follow the dispatcher or trained first-aider's instructions. If the casualty is unresponsive and breathing normally, use the recovery position where appropriate and keep checking breathing.
    • If they are not breathing normally, including abnormal gasping, start CPR as trained or directed by the dispatcher, and use an AED when available. Do not approach while the electrical danger remains.
    • Follow competent first-aid instructions for burns and other injuries without delaying CPR or emergency medical care.
  5. Follow up. A doctor will check the person for burns, fractures, dislocations and other injuries. The person may be admitted to hospital or a burns centre.

Inspection and maintenance strategies

Electrical equipment must be maintained to prevent danger. The type and frequency of user checks, inspections and testing depend on the equipment, the environment it is used in and the results of previous checks.

Electrical equipment should be checked by eye to spot early signs of damage or deterioration. A competent person should test it more thoroughly, often enough that there is little chance it will become dangerous between tests. Equipment used in a harsh environment should be tested more often than equipment that is less likely to be damaged or become unsafe.

It is good practice to decide how often each piece of equipment should be checked, write this down, perhaps as a checklist, make sure the checks are carried out accordingly and record the results. Change how often you check according to the number and seriousness of the faults found.

An appropriate maintenance system is strongly recommended. It can include:

User checkBefore use, equipmentdisconnectedFormal visual inspectionCompetent inspection;disconnect firstCombined inspection andtestPortable appliance testing
Figure 11.10 Three tiers of electrical maintenance

User checks (visual)

These should be done before most electrical equipment is used, with the equipment disconnected. Employees should look for:

These checks also apply to extension leads and their plugs and sockets. The user should check by eye when the equipment is taken into use and during use. Any faults should be reported to management and the equipment taken out of use immediately. Management should take effective steps to make sure the equipment is not used again until a competent person has repaired it. For example, disconnect safely, label and securely withdraw the defective equipment. Repairs or alteration of a plug belong to a competent person; users must not cut off or dismantle plugs as a routine response.

Formal visual inspections

You do not need to be an electrician to carry out a visual inspection, but you do need to know what to look for and have enough knowledge to avoid danger to yourself and others. Simple training can give you, or a member of staff, the basic electrical knowledge to carry out a visual inspection competently.

The competent inspector includes the user's checks and, where appropriate, disconnects the equipment and inspects a rewirable plug internally. Do not open a moulded plug. For a suitable rewirable plug check that:

Page 8 of 9 in this chapter · page 87 of 88 in the book